martes, 4 de diciembre de 2012

Health Alert Network | HAN-00337

Health Alert Network | HAN-00337

  • Emergency Preparedness & Response

  • Preparedness for All Hazards

  • Health Alert Network (HAN)

  • HAN Archive

  • 2012

  • HANThis is an official
    CDC HEALTH UPDATE
    Distributed via Health Alert Network
    December 3, 2012, 16:55 ET (4:55 PM ET)
    CDC HAN-0337

    Update: Additional Contamination Identified in Medical Products from New England Compounding Center

    Summary: As part of the ongoing investigation of the multistate outbreak of fungal meningitis and other infections, the Centers for Disease Control and Prevention (CDC) and the Food and Drug Administration (FDA) continue to test medical products from the New England Compounding Center (NECC) in Framingham, Mass.  CDC and FDA are reporting today additional microbial contamination identified in NECC products, which updates the November 1, 2012 Health Alert Network advisory. This update includes the following key points:
    • CDC and FDA have identified additional microbial contamination in unopened vials of betamethasone, cardioplegia, and triamcinolone solutions distributed and recalled from NECC.
    • These include bacteria known as Bacillus, and fungal species including Aspergillus tubingensis, Aspergillus fumigatus, Cladosporium species, and Penicillium species. 
    • Although rare, some of the identified Bacillus species can be human pathogens. Some of the fungal organisms identified, particularly Aspergillus fumigatus, are known to cause disease in humans. It is not known how product contamination with these organisms could affect patients clinically. 
    • To date, although CDC has received reports of illness in patients who have received the medications listed in the table below, including some patients who had evidence of meningeal inflammation, CDC and public health officials have no reports of laboratory-confirmed bacterial or fungal meningitis, spinal, or paraspinal infections caused by these products.
    • The available epidemiological and laboratory data do not, at this time, support evidence of an outbreak of infections linked to usage of non-methylprednisolone NECC products.
    • CDC's recommendations to healthcare providers for diagnosing and treating symptomatic patients who have received NECC products have not changed as a result of these findings.
    • CDC continues to recommend that clinicians remain alert for the possibility that infections may have resulted from injection of NECC products, and that routine laboratory and microbiologic tests, including bacterial and fungal cultures, should be obtained as deemed necessary by treating clinicians.
    • Clinicians should continue to report infections potentially related to NECC products to FDA's MedWatch and to state health departments.
    Background
    On September 26, 2012, NECC voluntarily recalled three lots of preservative-free methylprednisolone acetate (PF) 80mg/ml1 associated with the multistate outbreak of fungal meningitis and other infections. As previously confirmed by CDC and FDA, the fungus Exserohilum rostratum was identified from two different lots of NECC-supplied, preservative-free methylprednisolone acetate (Lot #06292012@26 and Lot #08102012@51); testing on the third implicated lot of preservative-free methylprednisolone acetate (Lot #05212012@68) has yet to identify fungal growth.  Two types of fungus not known to be human pathogens were also identified from product from the two tested lots, namely Rhodotorula laryngis and Rhizopus stolonifer. Among these fungal organisms, only Exserohilum rostratum has been associated with human infections in this outbreak.
    On October 6, NECC expanded its recall to include all products in circulation that were distributed from its facility in Framingham, Mass.  As part of the ongoing investigation, FDA and CDC have been testing various NECC products for evidence of contamination. Laboratory testing at CDC and FDA has found bacterial and/or fungal contamination in unopened vials of betamethasone, cardioplegia, and triamcinolone solutions distributed and recalled from NECC, as shown in the table below.

    Laboratory-Confirmed Organisms from Product Samples Associated with NECC Recalled Lots of Betamethasone, Cardioplegia, and Triamcinolone Solutions
    Medication
    Lot Number
    Bacterial and Fungal Contamination
    Betamethasone
    6 mg/mL injectable –5 mL per vial
    08202012@141
    Paenibacillus pabuli/amolyticus, Bacillus idriensis, Bacillus flexus, Bacillus simplex, Lysinibacillus sp., Bacillus niacini,
    Kocuria rosea, Bacillus lentus
    Betamethasone
    6 mg/mL injectable –5 mL per vial
    07032012@22
    Bacillus niabensis, Bacillus circulans
    Betamethasone
    12 mg/mL injectable – 5 mL per vial
    07302012@52
    Bacillus lentus, Bacillus circulans, Bacillus niabensis, Paenibacillus barengoltzii/timonensis
    Betamethasone
    6mg/mL injectable – 5 mL per vial
    08202012@44
    Bacillus lentus, Bacillus firmus, Bacillus pumilus
    Betamethasone
    6 mg/mL injectable – 5 mL per vial
    08152012@84
    Penicillium sp., Cladosporium sp.

    Triamcinolone*
    40mg/mL injectable – 1 mL per vial
    06062012@6
    Bacillus lentus, Bacillus circulans
    Triamcinolone
    40 mg/mL injectable – 2 mL per vial
    08172012@60
    Aspergillus tubingensis, Penicillium sp.
    Triamcinolone
    40mg/mL injectable – 10 mL per vial
    08242012@2
    Aspergillus fumigatus
    Cardioplegia solution
    265.5 mL per bag
    09242012@55
    Bacillus halmapalus/horikoshii, Brevibacillus choshinensis
    *Identification of other bacteria for this product is pending.
    Recommendations to Healthcare Providers
    FDA released a MedWatch Safety Alert on October 15 stating that the sterility of any injectable drugs, including ophthalmic drugs that are injectable or used in conjunction with eye surgery, and cardioplegic solutions produced by NECC is of significant concern.  The safety alert further advised healthcare providers to follow-up with patients who were administered any of these products purchased from or distributed by NECC on or after May 21, 2012. A sample notification letter to assist with this process is available.
    CDC’s recommendations to healthcare providers for diagnosing and treating symptomatic patients who have received NECC products have not changed as a result of the laboratory findings reported here. CDC continues to recommend that clinicians remain vigilant for the possibility that infections may have resulted from injection of NECC products, and that routine laboratory and microbiologic tests, including bacterial and fungal cultures, should be obtained as deemed necessary by treating clinicians.
    There has been no prior systematic surveillance for adverse events following epidural steroid injections; however, infection is a known, although likely rare, risk that has been documented in the medical literature.  To date, although CDC is aware of reports of illness in patients who have received these medications, including some patients who had evidence of meningeal inflammation, CDC and other public health officials have no reports of laboratory-confirmed bacterial or fungal meningitis, or spinal or paraspinal infections caused by these products.  The available epidemiological and laboratory data do not, at this time, support evidence of an outbreak of infections linked to usage of non-methylprednisolone NECC products.
    However, because it is possible that some of the organisms listed in the table above can cause human disease, clinicians should continue to include bacterial and/or fungal infection in the differential diagnosis when evaluating symptomatic patients who were exposed to these medications, including consideration of empiric antifungal therapy.
    Consultation with an infectious disease specialist is strongly encouraged to help make treatment decisions in these cases.  If the evaluation of these patients is suggestive of fungal infection, please consult existing CDC treatment guidance associated with this outbreak.
    Physicians should continue to report infections potentially related to NECC products to FDA's MedWatch and to state health departments.

    NECC lots of methylprednisolone acetate (PF) 80mg/ml:
         Methylprednisolone Acetate (PF) 80 mg/ml Injection, Lot #05212012@68, BUD 11/17/2012
         Methylprednisolone Acetate (PF) 80 mg/ml Injection, Lot #06292012@26, BUD 12/26/2012
         Methylprednisolone Acetate (PF) 80 mg/ml Injection, Lot #08102012@51, BUD 2/6/2013
    The Centers for Disease Control and Prevention (CDC) protects people's health and safety by preventing and controlling diseases and injuries; enhances health decisions by providing credible information on critical health issues; and promotes healthy living through strong partnerships with local, national, and international organizations.

    Categories of Health Alert Network messages:
    Health Alert - Requires immediate action or attention; highest level of importance
    Health Advisory - May not require immediate action; provides important information for a specific incident or situation
    Health Update - Unlikely to require immediate action; provides updated information regarding an incident or situation
    HAN Info Service - Does not require immediate action; provides general public health information
    ##This message was distributed to state and local health officers, public information officers, epidemiologists, HAN coordinators, and clinician organizations##

    No hay comentarios: